Astm c 1423 pdf files

Portland cement with enough water for the required strength and sand for proper consistency. Standard test method for sieve analysis of fine and coarse. Astm e1423 requires sealing of the test specimen to prevent air leakage. Standard test method for flexural strength of concrete. Astm documents, inasmuch as the reader will probably need the supplemental information provided in the guide to properly interpret the other documents. Standard specification for pressure vessel plates, alloy steel, 9 percent nickel, doublenormalized and. Astm c1423 16 standard guide for selecting jacketing materials. When astm a 307 bolts are submitted for testing and.

U values determined by nfrc test method astm c63, e 1423 and c1199 or simulation at certified lab. C1199 test method for measuring the steadystate thermal transmittance of fenestration systems using hot box methods. C142316 standard guide for selecting jacketing materials for thermal insulation piping. Astm c921 102015 standard practice for determining the. Astm c 1087 standard test method for determining compatibility of liquidapplied sealants with accessories used in structural glazing systems.

Standard practice for determining the steadystate thermal. Astm c452 standard test method for potential expansion of portlandcement mortars exposed to sulfate and astm c1012 test method for length changes of hydrauliccement mortars exposed to a sulfate solution. Portland cement astm c150 type i normal general purpose type ii modified resistance to alkali attack. A specification standard merely defines the measureable requirements that a product must meet to satisfy that standard. When property specifications are used, the compressive strength of the grout is determined in accordance with astm c1019, standard test method. Standard test method for density unit weight, yield, and. Currently, astm describes two accelerated test methods to evaluate the performance of hydraulic cements in sulfaterich environments. Astm c1767 19 standard specification for stainless steel. Guide c1423 provides guidance in selecting jacketing materials and their safe use.

Performance examination checklist astm c231 air content t. For annual book of astm standards volume information, refer to the standards document summary page on the astm website. Astm c1729 19 standard specification for aluminum jacketing for. For example, when determining the twist in plied yarn by the procedure for determining original twist, as the plied yarn is untwisted, a comparable amount of twist is reinserted in, or removed from, the singleyarn components. The standard provides a minimum base line of requirements and a basic set of. Certain versions of this product are designlights consortium dlc qualified. Referenced documents purchase separately the documents listed below are referenced within the subject standard but are not provided as part of the standard astm standards. Thermal transmittance of steel door and frame assemblies. Y d volume of concrete which the batch was designed to produce, yd 3or m y f volume of concrete produced per batch, ft 3 v total absolute volume of the component ingredients in the batch, ft 3or m v m volume of the measure, ft 3or m note 2the theoretical density is, customarily, a laboratory determi nation, the value for which is assumed to remain constant for all batches. Standard practice for sampling liquefied petroleum lp gases manual method. Astm c 920 standard specification for elastomeric joint sealants. Astm c 1248 standard test method for staining of porous substrate. Astm e142314 standard practice for determining steady state thermal transmittance of fenestration systems.

The test setup for flexural performance testing is shown in figure 1. First test the sample in accordance with test method c 117 through the. These documents tend to be very brief, and usually include a table of. C 31c 31m practice for making and curing concrete test. Astm c1161 testing fixture this method is used for the resistance to the bending test for the ceramic is mainly governed by astm c 1161. Standard test method for shear properties of sandwich core. The proposed astm test simulated expected field conditions more accurately than the aashto t 288 test. C 31 practice for making and curing concrete test specimens in the field2 c 78 test method for flexural strength of concrete using simple beam with third point loading2 c 192 practice for making and curing concrete test specimens in the laboratory2 c 617 practice for capping cylindrical concrete specimens2. Other heavy duty service at temperatures up to 650f 345c. C1423 guide for selecting jacketing materials for thermal insulation. Standard test method for thermal performance of building. Technical standards for insulation stainless steel ideal products. Astm d1423 d1423m 16 standard test method for twist in.

Washed aggregate complying with astm c 33, size no. Astm c6305 standard test method for thermal performance of building materials and envelope assemblies by means of a hot box apparatus. Astm e1423 14 standard practice for determining steady. Apparatus air meter has annual calibration funnel spout of a size permitting insertion through neck of top section spout long enough to extend to a point just above bottom of top section. The deflection rates suggested by astm c1609 2010 have been shown to cause premature failure banthia and islam, 20 and. May contain mineral or chemical admixtures, if approved by owners. The critical material properties included in astm c 534 and astm c1427 are thermal conductivity k factor, water vapor transmission wvt, water absorption, flexibility, and dimensional stability.

Astm c 1193 standard guide for use of joint sealants. Flame spread less than 25 and smoke developed less than 450. Our test results indicate that stable air complies with the requirements in aashto. Test method c 692 and subsequently monitored in accordance with test methods c 871. Properties, compositions, dimensional tolerances, alloys, tempers, and tensile strength. Add only as permitted by patching mortar manufacturer. The following bibliographic material is provided to assist you with your purchasing decision. Standard test method for rubber propertiesmeasurement. The right to access the electronic files of astm standards is for purposes of viewing for individual use only.

Astm e 84, astm e 162, astm e 662, imo ftp code part 2 and part 5, and ul 723. Meter aci concrete field testing techniciangrade i page 4 of 4 in order to merit a passing overall score on the performance examination, each individual step must be passed on either the first or second trial, or on the retrial following a voluntary suspension. C 33 specification for concrete aggregates c 51 terminology relating to lime and limestone as used by the industry c lo9c 109m test method for compressive strength of hydraulic cement mortarsusing 2in. Accelerated test for measuring sulfate resistance of. For horizontal or sloped airspaces reflective or nonreflective, testing shall include upward and downward heat flow. Astm d2194022012 standard test method for concentration of formaldehyde solutions by hplc significance and use 4. This specification pertains to quicklime and hydrated lime, either high calcium, dolomitic, or magnesium lime, for use in stabilization of soils. Interior finish classification, fire rated laminate. Ip65 rating per iec 60598 standard with optional ip66 rating. For reflective airspaces, the application of the astm c 63 test method shall comply with conditions and formula specified in astm c 1224 e.